Example Setups

Modular Spectroscopy Setups for Absorbance, Reflection, Emission & More

Ocean Optics provides a range of modular optical sensing solutions and the applications know-how to help you solve your measurement challenges. The basic setups described here will give you an idea of the thousands of configurations possible with our miniature, modular spectrometers and fiber optic accessories.

 

Featured Products for Absorbance in Gases:

Absorbance of Gases

Maya2000 Pro This high-resolution spectrometer is configured for UV absorbance in the sample setup. We use Grating #H7 set for 200-300 nm, with a 5 µm slit as entrance aperture and a detector collection lens for increased sensitivity.
D-2000 Deuterium source produces continuous output from ~215-400 nm
CUV-UV-10 Cuvette holder for 10-cm pathlength cuvettes
CV-Q-100 Cylindrical quartz cell with Teflon stopper; has volume of 28.2 mL
QP455-025-XSR-BX Pair of extreme solarization-resistant patch cord assemblies, 455 µm diameter, 0.25 m length
OceanView Spectroscopy software

Featured Products for Absorbance in Solutions:

UV-Vis Absorbance of Solutions

USB4000-UV-VIS General-purpose spectrometer is preconfigured for 200-850 nm and has a 25 µm slit and order-sorting filter
DH2000-BAL Balanced deuterium tungsten halogen light source provides illumination from 215-2000 nm
CUV-UV This sturdy cuvette holder accepts 1 cm pathlength cuvettes
CV-Q-10 A quartz cuvette is recommended for UV applications in particular
QP450-2-XSR Two 450 µm extreme solarization-resistant optical fibers will transmit and receive light in this setup
Absorbance Standards (optional) NIST-traceable photometric absorbance standards for 200-450 nm (STAN-ABS-UV) and 400-900 nm (STAN-ABS-VIS) ranges
OceanView Spectroscopy software

Featured Products for Fluorescence:

Fluorescence

USB4000-FL Spectrometer is preconfigured for fluorescence measurements from 360 – 1100 nm.
The spectrometer comes with a 200 µm slit and detector collection lens for increased light throughput.
QE Pro-FL Highly sensitive spectrometer specifically suited for low light-level applications such as fluorescence.

Featured Products for Upwelling and Downwelling:

Laser Analysis Setup

 

HR4000 high-resolution spectrometer High resolution spectrometer. We recommend configuring the spectrometer with an HC-1 grating for extended range (200-1050 nm), a 50 µm slit as the entrance aperture and a DET4-200-1100 detector with variable longpass filter and quartz window
DH2000-CAL UV-NIR light source used to calibrate the absolute spectral response of a radiometric system
QP400-2-UV-VIS Premium-grade patch cord for collecting signal
Gershun Tube Optical assembly that attaches to a spectrometer or SMA 905-terminated optical fiber to control the FOV of the setup
OceanView Spectrometer operating software

Featured Products for LED Measurement:

Ocean HDX Spectrometer anchored by High Definition Optics for high throughput, low stray light and great thermal stability
FOIS-1 Integrating sphere that collects light from emission sources such as LEDs
LED-PS Power supply powers the LED, displays the LED drive current and holds the LED in place
QP400-2-VIS-NIR Premium-grade patch cord directs light collected at integrating sphere to the spectrometer
HL-3-INT-CAL Radiometrically calibrated light source designed for use with an integrating sphere
OceanView Spectroscopy software

Featured Products for Laser Analysis:

NIR_Laser_Analysis_General

 

HR4000 high-resolution spectrometer We recommend configuring the spectrometer with Grating #6 set for 750-925 nm, with a 5 µm slit as the entrance aperture
FOIS-1 Fiber optic integrating sphere for collecting the signal
OPM series Optical Post Mounts Optical post mounts (multiple options available) for holding the integrating sphere and other components
QP400-2-VIS-NIR Premium-grade patch cord assembly, 2 m length, 400 µm diameter
OceanView Spectrometer operating software

Featured Products for Thin Film Metrology:

Example setup: Thickness Measurement

HR2000+ES High-resolution spectrometer with enhanced sensitivity is configured with an extended-range grating (200-1050 nm), 10 µm slit and variable longpass filter and quartz window (DET2B-200-1100)
HL-2000 Tungsten halogen light source (360-2400 nm)
QP400-7-UV-VIS Premium-grade 400 µm diameter fiber optic reflection probe; 2 m length
Reflection probe fixture options RPH-1 holds 0.25” (6.35 mm) diameter probes at 45° and 90° to the surface STAGE Single-point Reflection Stage holds 0.25” (6.35 mm) diameter probes and accommodates substrates up 150 mm in diameter
Reference standard options STAN-SSH high-reflectivity specular reflectance standard STEP-WAFER options are Si-SiO2 reference wafers for thickness measurements of thin films on silicon wafers and other substrates
OceanView Spectroscopy operating software

Featured Products for UV-Vis Reflection:

Reflected Color Setup Simplified

USB4000-UV-VIS General-purpose spectrometer preconfigured with 600 l/mm grating set to 200-850 nm, 25 µm entrance slit and order-sorting filter
DH-2000-BAL Deuterium-tungsten halogen light source (~215-2500 nm)
R400-7-VIS-NIR Reflection probe (6-around-1 fiber design), optimized for VIS-NIR response, 2 m length
RPH-1 Reflection probe (6-around-1 fiber design), optimized for VIS-NIR response, 2 m length
WS-1-SL Fixture for holding 1/4″ (6.35 mm) diameter reflection probes
OceanView Spectroscopy software

Featured Products for Reflected Color Measurement:

Ocean HDX Spectrometer anchored by High Definition Optics for high throughput, low stray light and great thermal stability
HL-2000 Tungsten halogen light source (360-2400 nm)
QR400-7-VIS-NIR Reflection probe (6-around-1 fiber design), optimized for VIS-NIR response, 2 m length
RPH-1 Fixture for holding 1/4″ (6.35 mm) diameter reflection probes
WS-1-SL Diffuse reflectance standard has 99% reflectivity from 400-1500 nm
OceanView Spectroscopy software

Featured Products for Oxygen Sensing:

Oxygen and pH SetupOxygen Sensing Components

NEOFOX-GT A compact optical instrument capable of measuring fluorescence lifetime, phase, and intensity for oxygen sensing.
RE-BIFBORO-2 Bifurcated optical fiber with borosilicate fiber bundle has one fiber leg to transmit excitation to the patch and one fiber leg to collect the response.
RedEye oxygen patches Select from among patch diameters (4 mm and 8 mm) and sensor formulations (general purpose coating, high-sensitivity coating or highly robust coating). Single patches and packs of 5 patches are available.
NeoFox Viewer Windows-based software allows users to collect, manage and analyze data with NeoFox systems.
Calibration Service Recommended for applications where the sample cannot be maintained at a constant temperature (±1 °C). Calibration service covers environments from 0 – 80°C and is optimized for the sensor coating formulation being used and the temperature and oxygen concentration ranges of the sample environment.

pH Sensing Components

Flame Spectrometer We recommend configuring the Flame spectrometer for visible measurements from 350-1000 nm and using a 50 µm entrance slit.
HL-2000 Tungsten halogen source provides VIS-NIR illumination.
RE-BIFBORO-2 Bifurcated optical fiber with borosilicate fiber bundle has one fiber leg to illuminate the patch and one fiber leg to collect the response.
PH-BCG-REFLECT These reflective pH patches can be used with colored or turbid samples, and are meant to be applied to the inner wall of a clear vessel or process flow. Each order comprises a pack of 5 sol gel-entrapped bromocresol green pH sensors.

Online purchases are not currently available. Please contact us directly for sales.